Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.552
Filtrar
1.
Int J Pediatr Otorhinolaryngol ; 180: 111961, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38705134

RESUMEN

OBJECTIVES: Adenoid hypertrophy causes impaired nasopharyngeal airways (NA) ventilation. However, it is difficult to evaluate the ventilatory conditions of NA. Therefore, this study aimed to analyze the nasopharyngeal airway resistance (NARES) based on computational fluid dynamics simulations and the nasopharyngeal airway depth (NAD) and adenoid hypertrophy grade measured on cephalometric cone-beam computed tomography images and determine the relationship between NAD and grade and NARES to ultimately assess using cephalometric measurements whether NA has airway obstruction defects. METHODS: Cephalogram images were generated from cone-beam computed tomography data of 102 children (41 boys; mean age: 9.14 ± 1.43 years) who received orthodontic examinations at an orthodontic clinic from September 2012 to March 2023, and NAD and adenoid grade and NARES values were measured based on computational fluid dynamics analyses using a 3D NA model. Nonlinear regression analyses were used to evaluate the relationship between NARES and NAD and correlation coefficients to evaluate the relationship between grade and NARES. RESULTS: NARES was inversely proportional to the cube of NAD (R2 = 0.786, P < 0.001), indicating a significant relationship between these variables. The resistance NARES increased substantially when the distance NAD was less than 5 mm. However, adenoid Grade 4 (75 % hypertrophy) was widely distributed. CONCLUSIONS: These study findings demonstrate that the ventilatory conditions of NA can be determined based on a simple evaluation of cephalogram images. An NAD of less than 5 mm on cephalometric images results in NA obstruction with substantially increased airflow resistance.


Asunto(s)
Tonsila Faríngea , Resistencia de las Vías Respiratorias , Tomografía Computarizada de Haz Cónico , Hidrodinámica , Hipertrofia , Nasofaringe , Humanos , Tonsila Faríngea/patología , Niño , Masculino , Femenino , Nasofaringe/diagnóstico por imagen , Nasofaringe/patología , Resistencia de las Vías Respiratorias/fisiología , Cefalometría , Obstrucción de las Vías Aéreas , Estudios Retrospectivos
2.
Respir Physiol Neurobiol ; 325: 104268, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38679307

RESUMEN

Obstructive sleep apnea (OSA) patients who use continuous positive airway pressure (CPAP) often complain of nasal dryness and nasal obstruction as side effects of CPAP. The physiological mechanisms by which CPAP may cause nasal dryness and nasal obstruction remain poorly understood. It has been hypothesized that CPAP interferes with the nasal cycle, abolishing the resting phase of the cycle and leading to nasal dryness. We performed rhinomanometry measurements in 31 OSA patients sitting, laid supine, and supine after 10 min of CPAP at 10 cmH2O. A posture change from sitting to supine led to more symmetric airflow partitioning between the left and right nostrils in the supine position. CPAP did not have a significant impact on nasal resistance, unilateral airflows, or airflow partitioning. Our results suggest that airflow partitioning becomes more symmetric immediately after changing to a supine position, while CPAP had no effect on nasal airflow, thus preserving the nearly symmetric airflow partitioning achieved after the posture change.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua , Postura , Rinomanometría , Apnea Obstructiva del Sueño , Humanos , Masculino , Postura/fisiología , Femenino , Persona de Mediana Edad , Apnea Obstructiva del Sueño/terapia , Apnea Obstructiva del Sueño/fisiopatología , Adulto , Resistencia de las Vías Respiratorias/fisiología , Obstrucción Nasal/fisiopatología , Obstrucción Nasal/terapia , Posición Supina/fisiología , Anciano
4.
Medicina (Kaunas) ; 60(3)2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38541172

RESUMEN

Background and Objectives: Data on characteristics of asthma in children with sickle cell disease (SCD) is conflicting. Recently, the L-arginine pathway has gained attention in the pathogenesis of asthma and SCD. This study aimed to determine the distinctive clinical and laboratory features and the role of arginine metabolism in asthmatic children with SCD. Materials and Methods: A total of 52 children and adolescents with SCD, including 24 with asthma (SCD-A) and 28 without asthma (SCD-NA), and 40 healthy controls were included. A questionnaire, atopy tests, fractional exhaled nitric oxide (FeNO), and lung function tests were employed. Serum metabolites of the arginine pathway were measured. The results of the three groups were compared. Results: The demographic characteristics and atopy markers of the three groups were similar. FEV1%, FEV1/FVC, MMEF%, and total lung capacity (TLC%) values of SCD-A patients were not significantly different from the SCD-NA group, but they were significantly lower than the values measured in the controls. FeNO values greater than 35 ppb were present only in the SCD-A group. In impulse oscillometry, median resistance values at 5 Hz (R5)% were higher in both SCD subgroups than in healthy controls (p = 0.001). The (R5-20/R5)% values were higher in the SCD-A group (p = 0.028). Serum arginine levels and arginine bioavailability indices were significantly lower in the SCD-A group than in the SCD-NA group and healthy controls (p = 0.003 and p < 0.001). Conclusions: Asthma in children with SCD was not associated with atopy or low FEV1/FVC levels. However, lower arginine bioavailability and higher FeNO levels differentiated asthma in patients with SCD. High R5% and (R5-20/R5)% values indicated increased airway resistance in SCD, with a predominance of small airway disease in asthmatics.


Asunto(s)
Anemia de Células Falciformes , Asma , Niño , Adolescente , Humanos , Adulto Joven , Resistencia de las Vías Respiratorias , Prueba de Óxido Nítrico Exhalado Fraccionado , Disponibilidad Biológica , Oscilometría/métodos , Espirometría , Óxido Nítrico/metabolismo , Pruebas de Función Respiratoria , Anemia de Células Falciformes/complicaciones
5.
Ann Biomed Eng ; 52(6): 1617-1624, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38433152

RESUMEN

Increased negative intrathoracic pressure that occurs during pharyngeal obstruction can increase thoracic fluid volume that may contribute to lower airway narrowing in individuals with obstructive sleep apnea (OSA) and asthma. Our previous study showed that fluid accumulation in the thorax induced by simulated OSA can increase total respiratory resistance. However, the effect of fluid shift on lower airway narrowing has not been investigated. To examine the effect of fluid accumulation in the thorax on the resistance of the lower airway. Non-asthma participants and individuals with (un)controlled asthma were recruited and underwent a single-day experiment. A catheter with six pressure sensors was inserted through the nose to continuously measure pressure at different sites of the airway, while a pneumotachograph was attached to a mouthpiece to record airflow. To simulate obstructive apneas, participants performed 25 Mueller maneuvers (MMs) while lying supine. Using the recordings of pressure sensor and airflow, total respiratory (RT), lower respiratory components (RL), and upper airway (RUA) resistances were calculated before and after MMs. Generalized estimation equation method was used to find the predictors of RL among variables including age, sex, body mass index, and the effect of MMs and asthma. Eighteen participants were included. Performing MMs significantly increased RT (2.23 ± 2.08 cmH2O/L/s, p = 0.003) and RL (1.52 ± 2.00 cmH2O/L/s, p = 0.023) in participants with asthma, while only RL was increased in non-asthma group (1.96 ± 1.73 cmH2O/L/s, p = 0.039). We found the model with age, and the effect of MMs and asthma severity generated the highest correlation (R2 = 0.69, p < 0.001). We provide evidence that fluid accumulation in the thorax caused by excessive intrathoracic pressure increases RL in both non-asthma and asthma groups. The changes in RL were related to age, having asthma and the effect of simulated OSA. This can explain the interrelationship between OSA and asthma.


Asunto(s)
Asma , Apnea Obstructiva del Sueño , Humanos , Asma/fisiopatología , Masculino , Femenino , Apnea Obstructiva del Sueño/fisiopatología , Adulto , Persona de Mediana Edad , Resistencia de las Vías Respiratorias , Modelos Biológicos
6.
Respir Med ; 224: 107564, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38360190

RESUMEN

BACKGROUND: Impulse oscillometry (IOS) is an effective tool for assessing airway mechanics and diagnosing obstructive airway disease (OAD) in children with sickle cell disease (C-SCD). Obesity is known to be associated with OAD, and untreated OAD often leads to hypoxia-related complications in C-SCD. Considering the increasing prevalence of obesity in C-SCD, it is important to explore the influence of body mass index (BMI) on OAD in this disease population. METHODS: A longitudinal retrospective chart review was conducted on 55 C-SCD (161 IOS observations) and 35 non-SCD asthmatic children (C-Asthma) (58 observations), primarily to investigate the association between BMI and airway resistance in C-SCD and C-Asthma. We conducted generalized linear mixed models (GLMM), adjusted for pharmacotherapies, to demonstrate the influence of BMI on total (R5), central (R20), and peripheral (R5-20) airway resistance and reactance (X5, resonant frequency (Fres)). We further compared age, BMI, and IOS indices between C-SCD and C-Asthma using the Mann-Whitney test. RESULTS: Age and BMI were not statistically different between the two groups. In C-SCD, BMI was associated with R5 (GLMM t-statistics:3.75, 95%CI:1.01,3.27, p-value<0.001*) and R20 (t-statistics:4.01, 95%CI:1.04,1.15, p-value<0.001*), but not with R5-20 or airway reactance. In asthmatics, BMI was not associated with IOS estimates except Fres (t-statistics: 3.93, 95%CI: -0.06, -0.02, p-value<0.001*). C-SCD demonstrated higher airway resistances (R5 and R20) and reactance (Fres) compared to C-Asthma (Mann-Whitney: p-values<0.05). CONCLUSION: BMI significantly influenced total and central airway resistance in C-SCD. While higher airway resistances reflected increased OAD in C-SCD than asthmatics, higher Fres perhaps indicated progressive pulmonary involvement in C-SCD.


Asunto(s)
Anemia de Células Falciformes , Asma , Niño , Humanos , Resistencia de las Vías Respiratorias , Índice de Masa Corporal , Estudios Retrospectivos , Estudios Longitudinales , Oscilometría , Espirometría , Pulmón , Asma/tratamiento farmacológico , Anemia de Células Falciformes/complicaciones , Obesidad
7.
Pediatr Pulmonol ; 59(5): 1394-1401, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38390766

RESUMEN

OBJECTIVE: While coronavirus disease 2019 (COVID-19) is generally considered to exhibit a less severe clinical course in children than in adults, studies have demonstrated that respiratory symptoms can endure for more than 3 months following infection in at least one-third of pediatric cases. The present study evaluates the respiratory functions of children aged 3-15 years within 3-6 months of their recovery from COVID-19 using impulse oscillometry (IOS) and compares them with the values of healthy children. METHODS: Included in this prospective cross-sectional study were 63 patients (patient group) aged 3-15 years who contracted COVID-19 between December 2021 and May 2022, as well as 57 healthy children as a control group, matched for age and sex. The demographic, clinical, and laboratory data of the patients were recorded, and respiratory function was assessed based on airway resistance (zR5, zR20, R5-20) and reactance (zX5, zX20, reactance area [AX], resonant frequency [Fres]) using an IOS device. RESULTS: There were no significant differences in the age, weight, height, and body weight z score values of the two groups (p > .05). While the zR5 and R5-20 levels of the patient group were higher (p = .008 and p < .001, respectively) than those of the controls, the zR20, AX, and Fres values did not differ significantly between the groups (p > .05). The parameters indicating the reactance, including zX5 and zX20, were significantly lower in the patient group than in the control group (p = .028 and p < .001, respectively). CONCLUSION: Total and peripheral airway resistances were found to be elevated in children who had recovered from COVID-19 in the preceding 3-6 months.


Asunto(s)
COVID-19 , Oscilometría , Pruebas de Función Respiratoria , SARS-CoV-2 , Humanos , Niño , COVID-19/fisiopatología , COVID-19/complicaciones , COVID-19/diagnóstico , Masculino , Femenino , Adolescente , Preescolar , Estudios Transversales , Oscilometría/métodos , Estudios Prospectivos , Pruebas de Función Respiratoria/métodos , Estudios de Casos y Controles , Resistencia de las Vías Respiratorias/fisiología , Pandemias , Neumonía Viral/fisiopatología , Neumonía Viral/diagnóstico , Betacoronavirus
8.
Sci Rep ; 14(1): 4644, 2024 02 26.
Artículo en Inglés | MEDLINE | ID: mdl-38409397

RESUMEN

Airborne transmission of pathogens plays a major role in the spread of infectious diseases. Aerosol particle production from the lung is thought to occur in the peripheral airways. In the present study we investigated eighty lung-healthy subjects of two age groups (20-39, 60-76 years) at rest and during exercise whether lung function parameters indicative of peripheral airway function were correlated with individual differences in aerosol particle emission. Lung function comprised spirometry and impulse oscillometry during quiet breathing and an expiratory vital capacity manoeuvre, using resistance (R5) and reactance at 5 Hz (X5) as indicators potentially related to peripheral airway function. The association between emission at different ventilation rates relative to maximum ventilation and lung function was assessed by regression analysis. In multiple regression analyses including age group, only vital capacity manoeuvre R5 at 15% to 50% of end-expiratory vital capacity as well as quiet breathing X5 were independently linked to particle emission at 20% to 50% of maximum ventilation, in addition to age group. The fact that age as predictive factor was still significant, although to a lower degree, points towards further effects of age, potentially involving surface properties not accounted for by impulse oscillometry parameters.


Asunto(s)
Resistencia de las Vías Respiratorias , Pulmón , Humanos , Adulto Joven , Adulto , Oscilometría , Pruebas de Función Respiratoria , Espirometría , Volumen Espiratorio Forzado
10.
BMC Pulm Med ; 24(1): 10, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38167026

RESUMEN

BACKGROUND: Idiopathic pulmonary fibrosis (IPF) is a progressive disease with a poor prognosis. Pulmonary function tests (PFTs) aid in evaluating the disease status of IPF. The clinical significance of oscillometry measurements in interstitial lung diseases has recently been reported. Our previous study showed that respiratory reactance (Xrs) measured by oscillometry reflected disease severity and predicted subsequent lung capacity decline in patients with IPF. However, the direct impact of Xrs on survival needs to be determined, and there are currently no reference values in oscillometry to predict prognosis. Therefore, this study aimed to investigate the association between oscillometry measurements, particularly Xrs, and survival in patients with IPF and to determine the cutoff values of Xrs that predict 3-year survival. METHODS: We analyzed the relationship between the measured values of PFT and oscillometry derived from 178 patients with IPF. Univariate and multivariate Cox proportional hazards analyses were performed to investigate the relationships between clinical indices at the time of the first oscillometry and survival. We performed the time-dependent receiver operating characteristic (ROC) curve analysis to set the optimized cutoff values of Xrs for 3-year survival prediction. We examined the discriminating power of cutoff values of Xrs on survival using the Kaplan-Meier method and the log-rank test. RESULTS: Xrs components, especially in the inspiratory phase (In), significantly correlated with the PFT values. In the multivariate analyses, Xrs (all of reactance at 5 Hz [X5], resonant frequency [Fres], and low-frequency reactance area [ALX] in the inspiratory phase) had a significant impact on survival (X5, p = 0.003; Fres, p = 0.016; ALX, p = 0.003) independent of age, sex, and other prognostic factors derived from the univariate analysis. The area under the ROC curve was 0.765, 0.759, and 0.766 for X5 In, Fres In, and ALX In, with cutoff values determined at - 0.98, 10.67, and 5.32, respectively. We found significant differences in survival after dividing patients using each of the cutoff values of Xrs. CONCLUSIONS: In patients with IPF, Xrs measured by oscillometry significantly impacted survival. We also determined the cutoff values of Xrs to discriminate patients with poor prognoses.


Asunto(s)
Resistencia de las Vías Respiratorias , Fibrosis Pulmonar Idiopática , Humanos , Oscilometría/métodos , Pulmón , Pruebas de Función Respiratoria/métodos , Fibrosis Pulmonar Idiopática/diagnóstico
11.
Curr Opin Crit Care ; 30(1): 89-96, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38085854

RESUMEN

PURPOSE OF REVIEW: The response to positive end-expiratory pressure (PEEP) in patients with chronic obstructive pulmonary disease (COPD) requiring mechanical ventilation depends on the underlying pathophysiology. This review focuses on the pathophysiology of COPD, especially intrinsic PEEP (PEEPi) and its consequences, and the benefits of applying external PEEP during assisted ventilation when PEEPi is present. RECENT FINDINGS: The presence of expiratory airflow limitation and increased airway resistance promotes the development of dynamic hyperinflation in patients with COPD during acute respiratory failure. Dynamic hyperinflation and the associated development of PEEPi increases work of breathing and contributes to ineffective triggering of the ventilator. In the presence of airflow limitation, application of external PEEP during patient-triggered ventilation has been shown to reduce inspiratory effort, facilitate ventilatory triggering and enhance patient-ventilator interaction. To minimize the risk of hyperinflation, it is advisable to limit the level of external PEEP during assisted ventilation after optimization of ventilator settings to about 70% of the level of PEEPi (measured during passive ventilation). SUMMARY: In patients with COPD and dynamic hyperinflation receiving assisted mechanical ventilation, the application of low levels of external PEEP can minimize work of breathing, facilitate ventilator triggering and improve patient-ventilator interaction.


Asunto(s)
Respiración con Presión Positiva , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Respiración Artificial , Enfermedad Pulmonar Obstructiva Crónica/terapia , Ventiladores Mecánicos , Resistencia de las Vías Respiratorias
12.
Am J Respir Crit Care Med ; 209(4): 444-453, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-37972230

RESUMEN

Rationale: Respiratory resistance (Rrs) and reactance (Xrs) as measured by oscillometry and their intrabreath changes have emerged as sensitive parameters for detecting early pathological impairments during tidal breathing. Objectives: This study evaluates the prevalence and association of abnormal oscillometry parameters with respiratory symptoms and respiratory diseases in a general adult population. Methods: A total of 7,560 subjects in the Austrian LEAD (Lung, hEart, sociAl, boDy) Study with oscillometry measurements (computed with the Resmon Pro FULL; Restech Srl) were included in this study. The presence of respiratory symptoms and doctor-diagnosed respiratory diseases was assessed using an interview-based questionnaire. Rrs and Xrs at 5 Hz, their inspiratory and expiratory components, the area above the Xrs curve, and the presence of tidal expiratory flow limitation were analyzed. Normality ranges for oscillometry parameters were defined. Measurements and Main Results: The overall prevalence of abnormal oscillometry parameters was 20%. The incidence of abnormal oscillometry increased in the presence of symptoms or diagnoses: 17% (16-18%) versus 27% (25-29%), P < 0.0001. All abnormal oscillometry parameters except Rrs at 5 Hz were significantly associated with respiratory symptoms/diseases. Significant associations were found, even in subjects with normal spirometry, with abnormal oscillometry incidence rates increasing by 6% (4-8%; P < 0.0001) in subjects with symptoms or diagnoses. Conclusions: Abnormal oscillometry parameters are present in one-fifth of this adult population and are significantly associated with respiratory symptoms and disease. Our findings underscore the potential of oscillometry as a tool for detecting and evaluating respiratory impairments, even in individuals with normal spirometry.


Asunto(s)
Pulmón , Enfermedades Respiratorias , Adulto , Humanos , Oscilometría , Respiración , Espiración , Espirometría , Volumen Espiratorio Forzado , Resistencia de las Vías Respiratorias
13.
J Am Nutr Assoc ; 43(2): 131-138, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37399335

RESUMEN

OBJECTIVE: To examine the effect of varying fatty acid composition in a HFM on eNO, pulmonary function, and airway resistance. METHODS: Fifteen individuals [6 M/9 F; 21.9 ± 1.5 years old] each completed three HFM conditions {SF, O6FA, and O3FA; 12 kcal/kg body weight, 63% total fat, and 0.72 g/kg sugar smoothies} in random order separated by at least 48 h. Airway inflammation assessed via eNO, pulmonary function measured using the maximum flow volume loop (MFVL) and airway resistance measured using impulse oscillometry (iOS) were taken at baseline, 2h and 4h postprandially. RESULTS: There was no difference in eNO or iOS across time in any condition or between conditions (p > 0.05). There was a significant time by condition effect for FEV1 post-HFM in the SF and O6FA conditions (p < 0.05). CONCLUSION: Different fatty acid compositions do not increase eNO or iOS in healthy, college-aged participants after consumption of a HFM, though the minimally processed meals with fruit added may contribute to these findings.


Asunto(s)
Resistencia de las Vías Respiratorias , Neumonía , Humanos , Adulto Joven , Adulto , Ácidos Grasos , Pulmón , Inflamación
14.
Eur Arch Otorhinolaryngol ; 281(3): 1301-1306, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37863857

RESUMEN

INTRODUCTION: Fractures in the pyriform buttress area adversely affect facial appearance and nasal airway patency. Nasal airway function has received less attention than aesthetic problems in the literature. This retrospective study classified the different fracture types in this area and determined their impact on nasal airway function. MATHODS: Three-dimensional computed tomography images of patients with fractures in the pyriform buttress area were analyzed to identify the exact fracture pattern. The nasal airway functions were evaluated and compared between patients with different fracture patterns using acoustic rhinometry, rhinomanometry, and the nasal obstruction symptom evaluation scale. RESULTS: Overall, 47 patients, including 16 with type I fractures (high fracture line; group I), 16 with type II fractures (intermediate fracture line; group II), and 15 with type III fractures (low fracture line; group III), were included in the study. The mean minimal cross-sectional area (MCA), total nasal inspiratory resistance (Tri) and total nasal expiratory resistance (Tre) of group I were 0.51 ± 0.06 cm2, 1.67 ± 0.11 kPa L-1 s-1, and 1.66 ± 0.12 kPa L-1 s-1, respectively; those of group II were 0.48 ± 0.07 cm2, 1.89 ± 0.15 kPa L-1 s-1, and 1.88 ± 0.14 kPa L-1 s-1, respectively; and those of group III were 0.36 ± 0.04 cm2, 1.94 ± 0.21 kPa L-1 s-1, and 2.01 ± 0.34 kPa L-1 s-1, respectively. The nasal obstruction symptom evaluation (NOSE) scale scores for groups I, II, and III were 7.188, 9.813, and 13.27, respectively. CONCLUSION: Therefore, the severity of the nasal airway obstruction depends on the displacement of the fractured bones in patients with fractures in the pyriform buttress area. The most profound nasal obstruction occurs in patients with the lowest fracture line.


Asunto(s)
Obstrucción Nasal , Humanos , Obstrucción Nasal/diagnóstico por imagen , Obstrucción Nasal/etiología , Estudios Retrospectivos , Nariz , Rinomanometría/métodos , Rinometría Acústica/métodos , Resistencia de las Vías Respiratorias
15.
Respir Physiol Neurobiol ; 320: 104200, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38036081

RESUMEN

BACKGROUND: The forced oscillation technique (FOT) enables non-invasive measurement of respiratory system impedance. Limited data exists on how changes in operating lung volume (OLV) impact FOT-derived measures of airway resistance (Rrs) and reactance (Xrs). OBJECTIVES: This study examined the reproducibility and responsiveness of FOT-derived measures of Rrs and Xrs during simulated changes in OLV. METHODS: Participants simulated breathing at six OLVs: total lung capacity (TLC), ∼50% of inspiratory reserve volume (IRV50), ∼two-times tidal volume (VT2), tidal volume (VT), ∼50% of expiratory reserve volume (ERV50), and residual volume (RV), on a commercially available FOT device. Each simulated OLV manuever was performed in triplicate and in random order. Total Rrs and Xrs were recorded at 5, 11, and 19 Hz. RESULTS: Twelve healthy participants (2 female) completed the study (weight: 76.5 ± 13.6 kg, height: 178.6 ± 9.7 cm, body mass index: 23.9 ± 3.1 kg/m2). Reproducibility of Rrs and Xrs at VT, VT2 and IRV50 was good to excellent (Range: ICC: 0.89-0.98, 95% confidence interval (CI): 0.70-0.98), while reproducibility at TLC, RV, and ERV50 was poor to excellent (Range: ICC: 0.60-0.98, 95% CI: 0.36-0.97). Rrs and Xrs were not different between VT and VT2 at any frequency (P > .05). With lung hyperinflation from VT to TLC, Rrs and Xrs decreased at all three frequencies (e.g., At 5 Hz Rrs: mean difference (MD): - 0.89, 95%CI: - 0.03 to - 1.75, P = .04; Xrs: MD: - 0.56, 95%CI: - 0.25 to - 0.86, P < .01). With lung hypoinflated from VT to RV, Rrs increased, and Xrs decreased for all frequencies (e.g., MD at 5 Hz, Rrs: MD: 2.31, 95%CI: 0.94-3.67, P < .01; Xrs: MD: -2.53, 95%CI: -4.02 to -1.04, P < .01). CONCLUSION: FOT-derived measures of airway Rrs and Xrs are reproducible across a range of OLV's, and are responsive to hyper- and hypo-inflation of the lung. To further understand the impact of lung hyper- and hypo-inflation on FOT-derived airway impedance additional study is required in individuals with pathological variations in operating lung volume.


Asunto(s)
Resistencia de las Vías Respiratorias , Pulmón , Humanos , Femenino , Reproducibilidad de los Resultados , Impedancia Eléctrica , Pruebas de Función Respiratoria/métodos , Mediciones del Volumen Pulmonar
16.
Am J Respir Crit Care Med ; 209(6): 716-726, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38016085

RESUMEN

Rationale: The impact of a household air pollution (HAP) stove intervention on child lung function has been poorly described. Objectives: To assess the effect of a HAP stove intervention for infants prenatally to age 1 on, and exposure-response associations with, lung function at child age 4. Methods: The Ghana Randomized Air Pollution and Health Study randomized pregnant women to liquefied petroleum gas (LPG), improved biomass, or open-fire (control) stove conditions through child age 1. We quantified HAP exposure by repeated maternal and child personal carbon monoxide (CO) exposure measurements. Children performed oscillometry, an effort-independent lung function measurement, at age 4. We examined associations between Ghana Randomized Air Pollution and Health Study stove assignment and prenatal and infant CO measurements and oscillometry using generalized linear regression models. We used reverse distributed lag models to examine time-varying associations between prenatal CO and oscillometry. Measurements and Main Results: The primary oscillometry measure was reactance at 5 Hz, X5, a measure of elastic and inertial lung properties. Secondary measures included total, large airway, and small airway resistance at 5 Hz, 20 Hz, and the difference in resistance at 5 Hz and 20 Hz (R5, R20, and R5-20, respectively); area of reactance (AX); and resonant frequency. Of the 683 children who attended the lung function visit, 567 (83%) performed acceptable oscillometry. A total of 221, 106, and 240 children were from the LPG, improved biomass, and control arms, respectively. Compared with control, the improved biomass stove condition was associated with lower reactance at 5 Hz (X5 z-score: ß = -0.25; 95% confidence interval [CI] = -0.39, -0.11), higher large airway resistance (R20 z-score: ß = 0.34; 95% CI = 0.23, 0.44), and higher AX (AX z-score: ß = 0.16; 95% CI = 0.06, 0.26), which is suggestive of overall worse lung function. The LPG stove condition was associated with higher X5 (X5 score: ß = 0.16; 95% CI = 0.01, 0.31) and lower small airway resistance (R5-20 z-score: ß = -0.15; 95% CI = -0.30, 0.0), which is suggestive of better small airway function. Higher average prenatal CO exposure was associated with higher R5 and R20, and distributed lag models identified sensitive windows of exposure between CO and X5, R5, R20, and R5-20. Conclusions: These data support the importance of prenatal HAP exposure on child lung function. Clinical trial registered with www.clinicaltrials.gov (NCT01335490).


Asunto(s)
Contaminación del Aire , Preescolar , Femenino , Humanos , Lactante , Embarazo , Contaminación del Aire/efectos adversos , Resistencia de las Vías Respiratorias/fisiología , Ghana/epidemiología , Pulmón , Mujeres Embarazadas
17.
Sci Rep ; 13(1): 21608, 2023 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-38062060

RESUMEN

No official clinical reference values have been established for MostGraph, which measures total respiratory resistance and reactance using the forced oscillation technique, complicating result interpretation. This study aimed to establish a reference range for MostGraph measurements and examine its usefulness in discriminating participants with asthma from controls (participants without any respiratory diseases). The study also aimed to investigate the effectiveness of deep learning in discriminating between the two aforementioned groups. To establish reference ranges, the MostGraph measurements of healthy controls (n = 215) were power-transformed to distribute the data more normally. After inverse transformation, the mean ± standard deviation × 2 of the transformed values were used to establish the reference ranges. The number of measured items outside the reference ranges was evaluated to discriminate patients with asthma (n = 941) from controls. Additionally, MostGraph measurements were evaluated using deep learning. Although reference ranges were established, patients with asthma could not be discriminated from controls. However, with deep learning, we could discriminate between the two groups with 78% accuracy. Therefore, deep learning, which considers multiple measurements as a whole, was more effective in interpreting MostGraph measurement results than use of reference ranges, which considers each result individually.


Asunto(s)
Asma , Aprendizaje Profundo , Humanos , Valores de Referencia , Espirometría/métodos , Pruebas de Función Respiratoria/métodos , Asma/diagnóstico , Resistencia de las Vías Respiratorias
19.
Int J Chron Obstruct Pulmon Dis ; 18: 2555-2563, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38022825

RESUMEN

Introduction: Specific resistance (SRaw) measurements in Chronic Obstructive Pulmonary Disease (COPD) patients may be performed by panting or tidal breathing. The aim of this study was to compare how breathing frequency affected SRaw in COPD and compare different tangent plotting methods. Methods: Fifteen COPD patients participated. Three protocols were performed: tidal 1 - spontaneous tidal breathing; tidal 2 - tidal breathing with a flow of ±1 L/sec; panting - 60 breaths per min. Effective (SReff), total (SRtot), ±0.5 L/s (SR0.5), and mid (SRmid) specific resistance were assessed. Results: The tidal breathing protocols provided similar results. Panting resulted in higher SReff (p = 0.0002) and SRtot (p < 0.0001) versus tidal breathing, but not SR0.5 or SRmid. Breathing frequency did not affect intra-test variance. SReff and SRtot measurements were similar, and were higher than SR0.5, during tidal breathing (p = 0.0014 and p < 0.0001 respectively) and panting (p = 0.0179 and p < 0.0001 respectively). SRtot was higher than SRmid during tidal breathing (p < 0.0001) and panting (p < 0.0001). Intra-test variance of SReff and SRtot were similar and showed the lowest percent coefficient of variation during both tidal breathing and panting. Conclusion: Panting and tidal breathing manoeuvres are not interchangeable in COPD patients. Panting widens the clubbing in the SRaw loop. SR0.5 and SRmid may underestimate abnormal physiology in COPD.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Humanos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Resistencia de las Vías Respiratorias/fisiología , Pruebas de Función Respiratoria , Respiración , Sistema Respiratorio
20.
Respir Med Res ; 84: 101027, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37717385

RESUMEN

BACKGROUND: The forced oscillation technique (FOT) may be useful for diagnosis and follow-up of respiratory diseases. It is unclear how global or regional alterations in airway resistance (Raw) and lung compliance (CL) alter FOT measurements. METHODS: A 2-compartment physical model of the respiratory system allowed to simulate variations in Raw, CL, and their heterogeneity during tidal breathing in an adult human. Five-Hz respiratory system resistance (Rrs5) and reactance (Xrs5), area of reactance (AX), resonance frequency (Fresp) and intrabreath variation in Rrs5 and Xrs5 were measured by FOT. Frequency dependance of resistance could not be studied in this model. Relationships between model characteristics (Raw, CL, and heterogeneity) and FOT measurements were explored by multiple regression. RESULTS: Rrs5 and intrabreath variation in Rrs5 and Xrs5 strongly associated with model characteristics (R2=0.753, 0.5 and 0.658). Associations of Xrs5, AX, and Fresp with model characteristics were weak (R2=0.214, 0.349 and 0.076). Raw heterogeneity was the main determinant of Rrs5 (Coeff=0.594), AX (Coeff=0.566) and intrabreath variation in Rrs5 and Xrs5 (Coeff=0.586 and 0.732). Regional extremes in Raw strongly determined Rrs5 (Coeff=1.006). Xrs5 did not strongly associate with any model characteristic. CONCLUSION: Raw heterogeneity and maximal regional Raw were the main determinants of FOT measurements, in particular Rrs5. Associations between CL and FOT measurements were weak.


Asunto(s)
Asma , Adulto , Humanos , Asma/diagnóstico , Pruebas de Función Respiratoria/métodos , Pulmón , Resistencia de las Vías Respiratorias , Respiración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA